为了防止制冷剂液体积蓄在压缩机中,应保证压缩机壳体底部的温度大于冷凝温度。
To prevent the liquid refrigerant accumulation in the compressor, ensure that the temperature at bottom of compressor case is higher than the condensing temperature.
运行电压必须在额定电压的±10%范围之内。
The running voltage shall be within ±10% of the rated voltage.
运行频率必须在额定频率的±2%范围之内。
The running frequency shall be within ±2% of the rated frequency.
压缩机在倾斜角5°范围内可以正常运转。
The compressor shall operate properly with tilting angle below 5°.
禁止压缩机横放、倒置、跌落,不要把压缩机放置在露天,必须将压缩机存放在-10℃~+65℃的室内。
Do not put the compressor horizontally or put it upside down. Do not let the compressor falls off. Do
not put the compressor in the open air, put the compressor inside the room where the temperatures
为了防止磁铁退磁,在设计变频系统时必须保证转子内的永久磁铁在任何情况下都不会被退磁;必须使用专用的变频器,一定不能使用感应电机所用的变频器或(直接)使用商用电源。
In order to prevent the permanent magnet to be demagnetised, the frequency conversion system must
ensure the permanent magnet not be demagnetised in any situation; use the spec
运行电压必须在260~350VDC范围之内。
The running voltage shall be within 260~350VDC.
运行频率必须在15~120Hz 的范围之内。
The running frequency shall be within 15~120Hz.